We have developed and produce a wide range of noncontact current sensors used for measuring direct, alternative or pulse current values, oscillographic testing of current signals, and galvanic isolation of electrical power circuits from metering circuits. The operation principle is based on measuring the value and direction of magnetic field created by controlled current in the gap of magnetic circuit with the help of Hall converter.

There are three designs available depending on the value of magnetic field to be tested.


Basic Specifications:


п/п

Parameters

CHCS-0,1

CHCS-1

CHCS-5

CHCS-20

CHCS-300

CHCS-600

1

Measured current range, А

0,1

1,0

5,0

20,0

300,0

600,0

2

Measurment accuracy within working temperature range, %, not more than

1

1

1

1

1

1

3

Input citcuit resistence, Ohm, not more than

1

0,1

-

-

-

-

4

Input circuit induction, mH, not more than

150

10

-

-

-

-

5

Resistance between metering and power circuits, МOhm, not more than

20

20

200

200

200

200

6

Frequency range, kHz
Option
А
Option B


5
 —


10
 —


12
 —


12
300


12
300


12
300

7

*Output signal, V

±10

±10

±10

±10

±10

±10

8

**Input current, mА

5-65

5-65

5-65

5-65

5-65

5-65

9

***Working temperature range, оС

-40...+55

-40..+55

-40...+55

-40...+55

-40...+55

-40...+55

10

Dimensions, mm

50х50х25

   — \\ -

50х70х30

   — \\ -

70x75x35

   — \\ -

11

Weight, g, not more than

50

70

100

100

200

200


* — may change depending on supply voltage
** — Depends on measurement accuracy
*** — Temperature range may be extended up to +125 оС

At present time there have been developed force-balance transducers for currents ranging from 0 .. ±100 А  to  0 .. ±1000А