Load Cell Series

Load cell series are used for measuring vertical component of tension arising at exposure to applied load.

May be used with different types of weighing systems which have many turnarounds (over 10E9), in turms of shocks.






Basic Specifications:
  • Measured load:   500 — 20.000 kg
  • Nominal voltage:  24 V
  • Allowable voltage:  18 — 30 V
  • Input current, YT:  not more than 100 mA
  • Output level: 4 — 20 mA
  • Frequency range:  0 — 10 Hz
  • Measurement accuracy:  1 %
  • Resolution: not less than 10 kg
  • Temperature range:  — 40 ... + 750 С


For more information please contact our specialists:
-
send a letter
- contact "VIST Group" by phone